Three-layer Anti-corrosion UPVC Corrugated Resin
Plastic Roof Sheet
As the upgrade product of Color Steel Sheet, FUGU PVC/UPVC/APVC/AUPVC Corrugated Sheet adopts advanced
co-extrusion technology and use super weather-resistance resin ASA and PVC as main material mixing with
UV resistance and other chemical adjuvant to enhance weather resistance ability and color durability.
Application: Widely used for agricultural trade market, passageway, residence house, temporary housing,
flat to sloping, villa,sunshade.
Three-layer Anti-corrosion UPVC Corrugated Resin Plastic Roof Sheet
Specification
Model |
FG-900W |
FG-900T |
FG-920 |
FG-1000 |
FG-1050 |
FG-1130 |
Overall Width |
900mm |
900mm |
920mm |
1000mm |
1050mm |
1130mm |
Useful Width |
800mm |
840mm |
850mm |
915mm |
960mm |
1050mm |
Thickness |
1.8 -4.0mm |
1.8 -4.0mm |
2.0-4.0mm |
2.0-4.0mm |
2.0-4.0mm |
1.8 -4.0mm |
Wave Height |
30mm |
18mm |
40mm |
45mm |
40mm |
25mm |
Length |
Within 5800mm and 11800mm . Or customer required |
Purlin Space |
600-1200mm |
Product Feature
1. Excellent Anti-corrosion
2. Excellent weather resistance
3. High Loading capacity
4. Good fireproof performance
5.Excellent heat insulation
6. Good sound-proof & noise-proof
7. Excellent Insulation resistance
8. Environment friendly
9.Light weight
Installation
Installation Of FUGU PVC/UPVC/APVC/AUPVC
Corrugated Sheet:
* Steel or wood purlin is better, purlins should be straight without deformation and two purlins must be in parallel
with same distance.
* Purlin Span: 2mm<800mm, 3.0mm<1000mm
* Integral lap joint at lateral side and lap-join around 200mm at vertical side
* drill hole before fix self-drilling screws. Consider expansion and contraction, the aperture have to be 30% at least
larger than screw diameter, the screw must not be over-tightened.
* The screws and fixing accessories must be not less than 4 sets/m2 to ensure the roof sheet structure have enough
strong against strong wind.
* At the overlap, roof sheets' placing order and paving should considering about the local prevailing wind
Notes of Installation:
* When maintenance the roof tiles should put a wooden board on the top of roof tile first, then the worker step on the wooden board.
* The roofing tile should not be over-bent in order to avoid damages.
* The thermal expansion and contraction of roof tile is different from steel, expansion space should be reserved and pay attention
to embedded depth. Otherwise the roof tile may deform and crack.
* It suggests use the special waterproof self-drilling screws and accessories during the installation. Especially at the eaves
should use the plastic fixture to compress tightly.
* It suggests use neutral silicone sealant and gasket to deal with the water leakage treatment.
APVC Corrugated Trapezoidal UPVC Plastic Roof Sheet
Company Profile
Hefei FUGU Building Material Co. Ltd is located at Hefei City which is the capital of Anhui province,
with the production site at Hefei and Wuhu city, covering an area of 21400 square meters, as the
professional manufacturer specialized in producing and marketing plastic septic tanks , certified by ISO9001
Quality Management System Certificate, ISO14001 environmental Management System and
OHSAS18001 Conformity of Occupational Health and Safety Management System.
And roof tiles since 1996. after years 'practice and experience accumulation, the annual production capacity of
Synthetic Resin Roof Tiles is more than 5,000,000 Square Meter, PVC/APVC Corrugated Sheet is more
than 5,000,00 Square Meter,Anti-corrosive Polyester Sheet is more than 3,000,000M, Anti-corrosive Polyester
Purlin is more than1,200,000 Square Meter, well-known by the worldwide gradually.
Three-layer Anti-corrosion UPVC Corrugated Resin Plastic Roof Sheet
Project
Widely used for agricultural trade market, passageway, residence house, temporary housing,
flat to sloping, villa,sunshade.Three-layer Anti-corrosion UPVC Corrugated Resin Plastic Roof Sheet